What Happens Inside the Burner
- The reset button only sends one spark attempt, so holding it down longer doesn't help it try harder.
- Inside the burner, an igniter and an oil nozzle have to fire together within a few seconds or the control shuts things down on purpose.
- A flame sensor, often called a cad cell, watches for the burner to actually light and tells the control to keep going or shut it off.
- If the cad cell doesn't see flame, the control locks out again even after a fresh reset, and that's a sign of a real fault.
- Oil has to reach the nozzle at the right pressure, so a clogged filter or a dirty nozzle can stop ignition with the electronics working fine.
- A soot-covered cad cell can read as no flame even when the burner lit, which sends the boiler into lockout for a reason that has nothing to do with the outage.
The reset button looks simple, but it only does one thing: it tells the primary control to try the ignition sequence one more time. Press it, and the control opens the oil valve, fires the igniter, and waits for the cad cell to confirm flame, all within a few seconds. If that sequence doesn't come together cleanly, the control shuts the burner down again on purpose. That's not the control being overly cautious. It's built that way because an oil burner that keeps dumping unburned oil into a firebox without lighting is a real hazard, so the control would rather quit and wait for someone to look at it. After a power outage, that sequence sometimes fails for reasons that have nothing to do with the outage itself. A nozzle partly clogged with old oil, a filter that was already due for a change, or a cad cell coated in soot from normal running can all stop the burner from lighting, or stop the control from recognizing that it lit. In that second case, the burner might actually fire and then shut off anyway, because the cad cell reports no flame even though there is one. A repeat lockout after a fresh reset usually means one of these parts needs attention, not another try at the button.